AQL Table | ANSI AQL Chart | AQL Calculator | AQI Service (2024)

What Does AQL? How to Read AQL Table?

AQL, or Acceptance Quality Limit, is defined as a “quality level that’s worst tolerance in standard ISO 2859-1, it’s a statistical tool to inspect a particular sample size for a given lot and set the maximum number of acceptable defects.

AQL Table | ANSI AQL Chart | AQL Calculator | AQI Service (1)In order words, it is the worst tolerable process average when a continuing series of lots is submitted for acceptance sampling.

There are normally three limits chosen, one for critical, major, and minor. Usually, each of these three limits is different for each category, and most Asia exporters are familiar with the type of setting,

AQL was also named “acceptance quality level” before, it is an important statistic for companies seeking Six Sigma level of quality control. and the AQL of a product would vary from industry to industry,

Companies dealing with extreme sports equipment or medical tools would have more stringent AQL, as acceptance of defective products could result in health risks.

AQL Calculator: Calculate Your Required Sample Size Quickly!

Keywords in AQL Inspection

  • Keywords: AQL Table/ANSI AQL Chart:

The standard definition ofAcceptance Quality Limit (AQL)is “the maximum defective percent (or the maximum number of defects per hundred units) that, for purpose of sampling inspection, can be considered satisfactory as a process average”.

  • Keywords: Three types of defects for consumer goods:

Critical Defects:Totally unacceptable defects, when accepted could lead to harm to the users. or regulations are not respected. It is defined by ZERO (AQL Table c=0)

Major Defects: Defects are usually not acceptable by the end-users, the AQL for a major defect is 1.5 or 2.5 (AQL 1.5 or AQL 2.5)

Minor Defects: Defects, which are not likely to reduce materially the usability of the product for its intended purpose but slightly differ from specified standards. most end users won’t mind it. The AQL for minor defects is 4.0

  • Keywords: Lot size in AQL Chart

The quantity of each product is the lot size, if you ordered different products, then each product considers a separate lot.

  • Keywords: General Inspection level (G-I, G-II, G-III)

Different inspection levels will command different numbers of samples to inspect. General Level II in single sampling plans is the normally used sampling method.

  • Keywords: Special Inspection level (S-1, S-2, S-3, S-4)

The special levels can be applied in cases where only a few samples should be checked, mostly the special levels are used only for certain on-site testings, and spot check during container loading supervision.

  • Keywords: AQL 2.5

When a product defect adversely affects the performance of the product or varies significantly from the specifications, or the defects cause the end customer to return the product, the inspector will the defects to be a “Major”, and the most common AQL inspection assigned to Major defects is 2.5. (Related: What does AQL 2.5 mean in a quality inspection?)

  • Keywords: AQL 4.0

Typically, minor defects are relatively small or insignificant issues, these issues won’t affect the product’s functionality or form, and customers won’t return the product based on the presence of one or very few minor defects on the product. but AQL 4.0 is typical for the acceptance of minor defects, your goods may fail inspection if the number of minor defects found beyond AQL 4.0

ANSI/ASQ Z1.4-2003 (R2013): Sampling Procedures and Tables for Inspection by Attributes is an acceptance sampling system to be used with switching rules on a continuing stream of lots for the Acceptance Quality Limit (AQL) specified.

ISO 2859-1:1999: Sampling procedures for inspection by attributes — Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection

It provides tightened, normal, and reduced plans to be applied for attributes inspection for percent nonconforming or nonconformities per 100 units.

AQL Table | ANSI AQL Chart | AQL Calculator | AQI Service (2)How to use the AQL Table?

A: Determine the sample size by using AQL Table

The AQL table will help you to determine the sampling size, we will need to inspect it according to your ordered quantity and your level of severity (G-I, II, or III).

And the standard level, the one used by default and by 98% of buyers is the General level G-II for a standard AQL inspection.

If your order has multiple references, ideally we should at least inspect a level II on each reference.

Indeed, for a standard order, the standard level II from the AQL table gives the minimum sampling size we should check per reference if we do not want to take additional risks.

If we inspect a G-II sampling size on multiple reference orders, then the AQL sampling size is diluted and divided by the number of references, increasing the risks as the sampling size must be representative enough.

In order to find the necessary sampling size to be inspected, we look at the first chart and find on the left side the range of items being produced in total.

You have the choice of levels I, II, and III, with Level III being the most stringent testing and level I being the least. As we said above, Level II is the standard and is most often used.

For example, if you are producing 8000 items, at AQL Chart level II you have the letter L, which in the second table says to inspect 200 items.

Another option is you can use our AQL Calculator to find your required sample size from AQL Table, please Click Here

B: Define the Acceptable Quality Limit

On the top of the second chart are the defect levels, ranging from 0 to 6.5. You can choose which level to apply for your type of defect: critical, major, and minor. (Learn more about Product inspection standards)

Usually, most importers will choose standard defect levels which are 0/2.5/4.0 but one can choose 1/1/1 if he wishes or 0/1.5/2.5 like in the automotive industry.

Using the standard 0/2.5/4.0 defect levels and a sample size of 200, we see that if you have more than 0 critical defects, 10 major defects, or 14 minor defects, you should reject your shipment. Of course, the decision about what to do after you received the inspection reports belongs to you, inspection only can give suggestions.

So most importers will put AQL sampling into the purchase contract and inspection checklist to avoid any misunderstanding in production, suppliers will be clear with your quality requirements. Importers will also wish to discuss all inspection findings with their vendor/manufacturer in order to improve whatever possible. In case the inspection results are very close to AQL limits, it is vital that you double-check if the AQL of found defects is acceptable to you or not.

Check the below chart of defect findings to better understand the acceptable quality limits

Sample sizeG-II AQL 0/1.5/2.5G-II AQL 0/2.5/4.0
01.52.502.54
K-125pcs0pcs5pcs7pcs0pcs7pcs10pcs
L-200pcs0pcs7pcs10pcs0pcs10pcs14pcs

More articles about how to use AQL Table:

  • What Are The General Inspection Levels? How To Choose The Correct Level For Inspection?
  • How To Use AQL Sampling To Determine If Goods Are Acceptable Or Not?
  • 3 Defect Classification In Product Inspection
AQL Table | ANSI AQL Chart | AQL Calculator | AQI Service (2024)

References

Top Articles
Latest Posts
Article information

Author: Nicola Considine CPA

Last Updated:

Views: 6272

Rating: 4.9 / 5 (49 voted)

Reviews: 80% of readers found this page helpful

Author information

Name: Nicola Considine CPA

Birthday: 1993-02-26

Address: 3809 Clinton Inlet, East Aleisha, UT 46318-2392

Phone: +2681424145499

Job: Government Technician

Hobby: Calligraphy, Lego building, Worldbuilding, Shooting, Bird watching, Shopping, Cooking

Introduction: My name is Nicola Considine CPA, I am a determined, witty, powerful, brainy, open, smiling, proud person who loves writing and wants to share my knowledge and understanding with you.