How to upgrade or downgrade virtual connect firmware in HPE using vcsu | GoLinuxCloud (2024)

Table of Contents

Advertisem*nt

To upgrade or downgrade virtual connect firmware you can either use smartupdate or vcsu. In this article I will show you the steps to upgrade or downgrade virtual connect firmware using vcsu.

How to upgrade or downgrade virtual connect firmware in HPE using vcsu | GoLinuxCloud (1)

What is VCSU utility?

The HPE BladeSystem c-Class Virtual Connect Support Utility enables administrators to upgrade VC-Enet and VC-FC firmware, and to perform other maintenance tasks remotely on both BladeSystem c-Class c7000 and c3000 Enclosures using a standalone command line utility. When the utility initiates a firmware upgrade process, VCSU performs an automatic health check, and then all modules are updated at the same time. The utility displays a message indicating that an update is in progress and the percentage completed. After the module firmware updates are complete, the utility activates all of the modules.

Overall Restrictions

There are certain restrictions which must be considered before you perform any upgrade or downgrade virtual connect firmware. These restrictions can be collected from the VCSU User Guide depending upon the vcsu version you plan to use.

To access the VCSU User Guide, navigate to "Hewlett Packard Enterprise Information Library"

  • Select "BladeSystem" under "Products & Solutions"
  • Select "Virtual Connect for c-Class BladeSystem" under "Models / Subcategories"
  • Next download the respective Virtual Connect Support Utility document
ALSO READ: Solved: Device in bay #X power delayed until VC profile is applied

Download Virtual Connect Firmware Binary

To perform upgrade or downgrade virtual connect firmware you need access to the VC binary file. You can download the VC binary file from the official HPE page. Under "Revision History" you can check the set of different Virtual Connect Firmware available and choose one accordingly. Download the binary file and keep it locally on the system using which you wish to perform upgrade/downgrade virtual connect firmware.

HINT:

In this article I am using RHEL 7 Linux host to trigger the VC firmware upgrade/downgrade but you can use the same command on Windows Host

Download Virtual Connect Support Utility

You can use Windows Or Linux to perform upgrade or downgrade virtual connect firmware. Accordingly based on your environment you can download vcsu for Linux or Windows host. Navigate to "Revision History" tab to get the various vcsu utility version.

Upgrade Virtual Connect Firmware

If you wish to upgrade multiple HPE Virtual Connect Firmware in parallel then read:Step-by-Step guide to upgrade multiple HPE VC firmware with SUM

Advertisem*nt

To upgrade the virtual connect firmware you can use below syntax:

 vcsu -a update -i <IP> -u <USER> -p <PWD> -l <FILE> [-f <FORCE>] [-vcu <VCM USER> -vcp <VCM PASS>] [-oe <ORDER>] [-of <ORDER>] [-q] [-we <DELAY>] [-wf <DELAY> ] [-cp <CFG PASS>] [-s <PORT>] [-e <PORT>]

Here,

 IP = IP Address of the active Onboard Administrator in enclosure USER = Name of the Onboard Administrator user with Administrator privileges to access all enclosure interconnect bays PWD = Password of the Onboard Administrator user Use * to prompt for password FILE = Full path to Virtual Connect package file FORCE = OPTIONAL. Comma separated list of one or more of the following: version: Allow update of same firmware version health: Allow update of Degraded or Failed modules VCM USER = Name of Virtual Connect Manager user with Domain privileges Required if Enclosure is in a Virtual Connect Manager Domain N/A if Enclosure is not in a Virtual Connect Manager Domain VCM PASS = Password for Virtual Connect Manager user -q = OPTIONAL. Specifies firmware update to not prompt for confirmation prior to update, and to use the default answer for the confirmation ('YES') ORDER = OPTIONAL. Specifies the order that modules will be activated -oe = VC-Enet Activation Order -of = VC-FC Activation Order parallel = All modules will be activated at once odd-even = Backup module is activated first. Force failover of VCM is done and then primary module is activated. Then modules in odd bays are activated and finally modules in even bays are activated (Enet Default) serial = Backup module is activated first. Force failover of VCM is done and then primary module is activated. Then remaining modules are activated one at a time starting from the lowest bay number (FC Default) manual = Modules will be updated but not activated DELAY = OPTIONAL. Delay in minutes between activations of bays -we = VC-Enet Delay -wf = VC-FC Delay Default is 0 or no delay. Maximum is 60 minutes CFG PASS = OPTIONAL. Password for Config Backup and Support Dump Encryption of Virtual Connect Manager Domain. Only used in Virtual Connect 3.00 and later Mandatory if the Virtual Connect domain is in FIPS mode PORT = TCP Port for VC-FC Updates -s = First port in allowed range. Default: 1024 -e = Last port in range. Default: 65535

In the below example I will perform firmware upgrade on my HP VC Flex-10/10D Module of the Virtual Connect from C7000 Enclosure. Here my Virtual Connect Binary file is available at /tmp/test/vcfwall475.bin and my existing VC firmware version is 4.62

HINT:

The VC firmware upgrade may take ~45 minutes to 1 hour to complete.

# vcsu -a update -i 10.43.142.118 -u HPadmin -p Passw0rd -l /tmp/test/vcfwall475.bin -vcu HPadmin -vcp Passw0rd -q -oe serial -we 5------------------------------------------------------------------------------- HPE BladeSystem c-Class Virtual Connect Support Utility Version 1.14.0 (Build 11) Build Date: Oct 10 2018 21:08:42 Copyright (C) 2006-2018 Hewlett Packard Enterprise Development LP All Rights Reserved-------------------------------------------------------------------------------The following modules will be updated:===============================================================================Enclosure Bay Module Current Version New Version===============================================================================SGH709YY1B 1 HP VC 4.62 4.75 Flex-10/10D 2018-01-26T07:20:40Z 2018-12-03T17:07:27Z Module-------------------------------------------------------------------------------SGH709YY1B 2 HP VC 4.62 4.75 Flex-10/10D 2018-01-26T07:20:40Z 2018-12-03T17:07:27Z Module-------------------------------------------------------------------------------During the update process, modules being updated will be temporarilyunavailable. In addition, the update process should NOT be interrupted byremoving or resetting modules, or by closing the application. Interruptingthe update or the modules being updated may cause the modules to not be updatedproperly.The following modules were updated successfully:======================================================================Enclosure Bay Module New Version======================================================================SGH709YY1B 1 HP VC Flex-10/10D Module 4.75 2018-12-03T17:07:27ZSGH709YY1B 2 HP VC Flex-10/10D Module 4.75 2018-12-03T17:07:27ZTotal execution time: 00:34:16VCSU log file is available at the following location: /root/vcsu-7143.log
ALSO READ: Fix: the domain status of virtual connect manager is not ok update will not continue

Downgrade Virtual Connect Firmware

With VCSU you can downgrade virtual connect firmware to a previously installed and running version of VC. Ideally to downgrade virtual connect firmware it is recommended fro, HPE to delete/destroy the existing VC domain and then perform VC downgrade but with later vcsu versions this can also be done without destroying the VC domain. But this has it's own set of restrictions.

Read the below set of restrictions thoroughly before proceeding with downgrade of Virtual Connect firmware

ALSO READ:

How to upgrade or downgrade VC firmware when Interconnect Modules are showing Incompatible State

Restrictions

The following restrictions apply:

  • You must be running VC version 3.70 or higher to perform a downgrade.
  • You cannot downgrade to a VC version lower than version 3.17.
  • A previous upgrade must have been performed on the configuration using VCSU 1.7.0 or higher.
  • All servers in the domain must be powered off.
  • Multiple, consecutive firmware downgrades are not allowed.
  • You can downgrade only to the version previously installed and running on the primary module.
  • The VC configuration, including physical connections, uplink port connections, and module positions in the enclosure, must be identical to the target downgrade configuration.
  • The VC credentials must be the same before and after the downgrade. After the downgrade, you cannot change the password for the account used to perform the downgrade.
  • The primary E-net module must be in the lowest bay number.
  • If the primary VC module DIP switch is set to FIPS mode, VC firmware cannot be downgraded to a non-FIPS capable version.

NOTE:

The list of restrictions may vary depending upon the VCSU version. The above list is for vcsu-1.4. It is recommended to check the respective VCSU User Guide.

For example:

# vcsu -a update -i 10.43.142.118 -u HPadmin -p Passw0rd -l /tmp/test/vcfwall462.bin -vcu HPadmin -vcp Passw0rd -q -oe serial -we 5------------------------------------------------------------------------------- HPE BladeSystem c-Class Virtual Connect Support Utility Version 1.14.0 (Build 11) Build Date: Oct 10 2018 21:08:42 Copyright (C) 2006-2018 Hewlett Packard Enterprise Development LP All Rights Reserved-------------------------------------------------------------------------------The following modules will be updated:===============================================================================Enclosure Bay Module Current Version New Version===============================================================================SGH709YY1B 1 HP VC 4.75 4.62 Flex-10/10D 2018-12-03T17:07:27Z 2018-01-26T07:20:40Z Module-------------------------------------------------------------------------------SGH709YY1B 2 HP VC 4.75 4.62 Flex-10/10D 2018-12-03T17:07:27Z 2018-01-26T07:20:40Z Module-------------------------------------------------------------------------------During the update process, modules being updated will be temporarilyunavailable. In addition, the update process should NOT be interrupted byremoving or resetting modules, or by closing the application. Interruptingthe update or the modules being updated may cause the modules to not be updatedproperly.The following modules were updated successfully:======================================================================Enclosure Bay Module New Version======================================================================SGH709YY1B 1 HP VC Flex-10/10D Module 4.62 2018-01-26T07:20:40ZSGH709YY1B 2 HP VC Flex-10/10D Module 4.62 2018-01-26T07:20:40ZTotal execution time: 00:38:27VCSU log file is available at the following location: /root/vcsu-5136.log

Just use the older VC firmware binary file with "-l" option and VCSU will automatically start the VC FW downgrade.

ALSO READ: Solved: Device in bay #X power delayed until VC profile is applied

Lastly I hope the steps from the article to upgrade or downgrade virtual connect firmware in HPE using vcsu was helpful. So, let me know your suggestions and feedback using the comment section.

Didn't find what you were looking for? Perform a quick search across GoLinuxCloud

How to upgrade or downgrade virtual connect firmware in HPE using vcsu | GoLinuxCloud (2024)

FAQs

How do I downgrade virtual connect firmware? ›

Run through the following procedure for each chassis:
  1. Launch the VCSU utility, vcsu.exe.
  2. Enter update as the action.
  3. Enter the OA IP Address of a chassis.
  4. Enter the OA Credentials.
  5. Enter the firmware package . ...
  6. Accept the default settings for Bay Number and backup password.
Jun 29, 2011

How do I update my HPE Virtual Connect firmware? ›

To perform upgrade or downgrade virtual connect firmware you need access to the VC binary file. You can download the VC binary file from the official HPE page. Under "Revision History" you can check the set of different Virtual Connect Firmware available and choose one accordingly.

How to change firmware version? ›

How to update your router's firmware (and why you should be doing it regularly)
  1. Get your router's IP address through the ipconfig command. ...
  2. Get your router's IP address in Windows. ...
  3. Sign into your router. ...
  4. Look for firmware update setting. ...
  5. Check for an update. ...
  6. Let the update install.
Apr 20, 2023

Can you downgrade VM hardware version? ›

To downgrade virtual machine hardware, power off the virtual machine and perform one of these options: Revert to a snapshot created before upgrading the virtual machine hardware. For more information, see Reverting Snapshots in the vSphere Virtual Machine Administration Guide.

How do I check my HPE firmware version? ›

You can check the firmware version from the MP. This will show you your current firmware version. There are multiple ways to upgrade it. The way I prefer doing it is through the HP-UX patches which can be installed using swinstall to upgrade all the firmware.

How to update firmware via iLO? ›

Updating firmware using iLO web interface
  1. Using a web browser, connect to the iLO web interface using the iLO IP address or PQDN/FQDN.
  2. Select Firmware & OS Software.
  3. Select Update Firmware.
  4. Verify the file location is set to Local file.
  5. Select Browse..., and then select the flash file.
  6. Click the Flash button.

Can I downgrade TP Link router firmware? ›

I refer to TPLink Archer C6 EU (AC 1200) router. The latest firmware 1.0. 3 is designed in such a way that once you upgrade to this version, you will not be allowed to downgrade any more.

How do I revert or downgrade my Epson firmware? ›

While the printer is off, press and hold power, down arrow, left arrow and cancel buttons at the same time, until your ROM menu appears on your printer's display. Download and run the older version of the firmware installation package on your computer.

Can I downgrade router firmware? ›

Yes, you can downgrade RouterOS, but only until the factory installed version, which you can check with this command: ? The factory-software is the oldest version supported by this device. Before contemplating a downgrade procedure, remember that older versions can contain bugs and security issues.

References

Top Articles
Latest Posts
Article information

Author: Jeremiah Abshire

Last Updated:

Views: 5973

Rating: 4.3 / 5 (54 voted)

Reviews: 85% of readers found this page helpful

Author information

Name: Jeremiah Abshire

Birthday: 1993-09-14

Address: Apt. 425 92748 Jannie Centers, Port Nikitaville, VT 82110

Phone: +8096210939894

Job: Lead Healthcare Manager

Hobby: Watching movies, Watching movies, Knapping, LARPing, Coffee roasting, Lacemaking, Gaming

Introduction: My name is Jeremiah Abshire, I am a outstanding, kind, clever, hilarious, curious, hilarious, outstanding person who loves writing and wants to share my knowledge and understanding with you.